{"id":3875,"date":"2017-08-12T18:58:11","date_gmt":"2017-08-12T18:58:11","guid":{"rendered":"https:\/\/andromedichyperthermia.com\/deep-local-hyperthermia-meht\/"},"modified":"2026-02-06T11:09:41","modified_gmt":"2026-02-06T11:09:41","slug":"modulowana-hipertermia-rf-mht","status":"publish","type":"page","link":"https:\/\/andromedichyperthermia.com\/pl\/modulowana-hipertermia-rf-mht\/","title":{"rendered":"Modulowana hipertermia RF &#8211; 13,56 MHz mHT"},"content":{"rendered":"<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"@id\": \"https:\/\/andromedichyperthermia.com\/pl\/modulowana-hipertermia-rf-mht\/#article\",\n      \"mainEntityOfPage\": {\n        \"@type\": \"WebPage\",\n        \"@id\": \"https:\/\/andromedichyperthermia.com\/pl\/modulowana-hipertermia-rf-mht\/\"\n      },\n      \"headline\": \"Modulowana Hipertermia RF - 13.56 MHz mHT\",\n      \"description\": \"Modulowana hipertermia RF (mHT) to nowatorska terapia cieplna, kt\u00f3ra selektywnie niszczy kom\u00f3rki nowotworowe, chroni\u0105c zdrowe tkanki. Ta innowacja medyczna najnowszej generacji dostarcza precyzyjn\u0105, kontrolowan\u0105 i g\u0142\u0119bok\u0105 energi\u0119 przy u\u017cyciu fali radiowej 13,56 MHz, zwi\u0119kszaj\u0105c skuteczno\u015b\u0107 chemioterapii, radioterapii i immunoterapii.\",\n      \"image\": {\n        \"@type\": \"ImageObject\",\n        \"url\": \"https:\/\/andromedichyperthermia.com\/wp-content\/uploads\/2025\/07\/modulated-RF-HT-selective-cancer-cells-300x213.jpg\",\n        \"width\": 300,\n        \"height\": 213,\n        \"caption\": \"Selektywne niszczenie kom\u00f3rek nowotworowych przez modulowan\u0105 hipertermi\u0119 RF\"\n      },\n      \"datePublished\": \"2025-07-28T00:00:00+02:00\",\n      \"dateModified\": \"2026-02-06T13:00:00+02:00\",\n      \"author\": { \"@id\": \"https:\/\/andromedichyperthermia.com\/#organization\" },\n      \"publisher\": { \"@id\": \"https:\/\/andromedichyperthermia.com\/#organization\" },\n      \"keywords\": [\n        \"Modulowana hipertermia RF\", \"mHT\", \"13.56 MHz\", \"selektywne leczenie raka\",\n        \"onkologia\", \"Andromedic HyDeep 600WM\", \"efekt abscopalny\", \"immunogenna \u015bmier\u0107 kom\u00f3rki\",\n        \"ICD\", \"mikro\u015brodowisko guza\", \"poprawa prze\u017cycia\", \"jako\u015b\u0107 \u017cycia\"\n      ],\n      \"about\": [\n        {\n          \"@type\": \"MedicalTherapy\",\n          \"name\": \"Modulowana Hipertermia RF\",\n          \"alternateName\": [\"mHT\", \"Hipertermia RF\", \"Termoterapia\"]\n        },\n        {\n          \"@type\": \"MedicalCondition\",\n          \"name\": \"Nowotw\u00f3r\",\n          \"alternateName\": [\"Kom\u00f3rki rakowe\", \"Guzy\", \"Patologie onkologiczne\"]\n        },\n        {\n          \"@type\": [\"MedicalDevice\", \"Product\"],\n          \"name\": \"Andromedic HyDeep 600WM\",\n          \"image\": \"https:\/\/andromedichyperthermia.com\/wp-content\/uploads\/2025\/07\/HY-DEEP-600WM-mEHT-device-main.jpg\",\n          \"description\": \"HyDeep 600 WM to zaawansowany system\/urz\u0105dzenie do hipertermii onkologicznej, system\/urz\u0105dzenie do g\u0142\u0119bokiej hipertermii lokalnej, system\/urz\u0105dzenie do modulowanej hipertermii RF oraz system\/urz\u0105dzenie do elektro-hipertermii. Wykorzystuje modulowan\u0105 cz\u0119stotliwo\u015b\u0107 radiow\u0105 13,56 MHz o g\u0142\u0119boko\u015bci penetracji do 38,4 cm.\",\n          \"sku\": \"HYDEEP-600WM\",\n          \"manufacturer\": { \"@id\": \"https:\/\/andromedichyperthermia.com\/#organization\" },\n          \"url\": \"https:\/\/andromedichyperthermia.com\/pl\/urzadzenie-do-hipertermii-andromedic\/\",\n          \"offers\": {\n            \"@type\": \"Offer\",\n            \"url\": \"https:\/\/andromedichyperthermia.com\/pl\/urzadzenie-do-hipertermii-andromedic\/\",\n            \"availability\": \"https:\/\/schema.org\/InStock\",\n            \"price\": \"0.00\",\n            \"priceCurrency\": \"EUR\",\n            \"description\": \"Cena dost\u0119pna na zapytanie\"\n          },\n          \"review\": {\n            \"@type\": \"Review\",\n            \"reviewRating\": { \"@type\": \"Rating\", \"ratingValue\": \"5\", \"bestRating\": \"5\" },\n            \"author\": { \"@type\": \"Person\", \"name\": \"Veronica Iatan\" },\n            \"reviewBody\": \"Specyficzne protoko\u0142y systemu HyDeep 600WM stanowi\u0105 doskona\u0142y post\u0119p w wynikach klinicznych hipertermii.\"\n          }\n        }\n      ],\n      \"mentions\": [\n        { \"@type\": \"Thing\", \"name\": \"13.56 MHz\" },\n        { \"@type\": \"Thing\", \"name\": \"Modulacja RF\" },\n        { \"@type\": \"Thing\", \"name\": \"Efekt elektromagnetyczny\" },\n        { \"@type\": \"Thing\", \"name\": \"Efekt abscopalny\" },\n        { \"@type\": \"Thing\", \"name\": \"Immunogenna \u015bmier\u0107 kom\u00f3rki\", \"alternateName\": \"ICD\" },\n        { \"@type\": \"Thing\", \"name\": \"Mikro\u015brodowisko guza\" }\n      ],\n      \"citation\": [\n        \"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC5356646\/\",\n        \"https:\/\/www.mdpi.com\/2072-6694\/15\/18\/4569\",\n        \"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC9939221\/\"\n      ]\n    },\n    {\n      \"@type\": \"MedicalOrganization\",\n      \"@id\": \"https:\/\/andromedichyperthermia.com\/#organization\",\n      \"name\": \"Andromedic Hyperthermia\",\n      \"url\": \"https:\/\/andromedichyperthermia.com\/pl\/\",\n      \"logo\": {\n        \"@type\": \"ImageObject\",\n        \"url\": \"https:\/\/andromedichyperthermia.com\/logo.png\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<div class=\"mht-clinical-container\" style=\"max-width: 1100px; margin: 0 auto; font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; color: #2c3e50; line-height: 1.7;\">\n<header style=\"border-bottom: 3px solid #004a99; margin-bottom: 30px; padding-bottom: 20px;\">\n<h1 style=\"color: #004a99; font-size: 2.4em; margin-bottom: 10px;\">Modulowana hipertermia RF \u2013 Technologia mHT 13,56 MHz<\/h1>\n<p style=\"font-size: 1.15em; font-weight: 400;\">Modulowana hipertermia RF (mHT) to zaawansowana terapia ciep\u0142em, kt\u00f3ra wykorzystuje <strong>synergi\u0119 efekt\u00f3w termicznych i nietermicznych (elektromagnetycznych)<\/strong> do ogrzewania i niszczenia kom\u00f3rek nowotworowych w spos\u00f3b <strong>SELEKTYWNY<\/strong>, bez uszkadzania zdrowych kom\u00f3rek.<\/p>\n<\/header>\n<div style=\"display: flex; flex-wrap: wrap; gap: 40px; margin-bottom: 50px; align-items: flex-start;\">\n<div style=\"flex: 1; min-width: 320px;\">\n<p>mHT to innowacja medyczna najnowszej generacji, kt\u00f3ra dostarcza do kom\u00f3rek nowotworowych <strong>selektywn\u0105, kontrolowan\u0105 i g\u0142\u0119bok\u0105 energi\u0119 (hipertermiczn\u0105 + elektromagnetyczn\u0105)<\/strong> przy u\u017cyciu sprz\u0119\u017conej pojemno\u015bciowo cz\u0119stotliwo\u015bci radiowej 13,56 MHz z modulacj\u0105 amplitudy.<\/p>\n<div style=\"background: #f0f7ff; border-left: 5px solid #004a99; padding: 20px; margin: 20px 0;\">\n<h2 style=\"margin-top: 0; color: #004a99; font-size: 1.3em;\">Wyj\u0105tkowe g\u0142\u0119bokie dzia\u0142anie w onkologii<\/h2>\n<p>mHT 13,56 MHz z u\u017cyciem 2 elektrod mo\u017ce penetrowa\u0107 do <strong>38,4 cm g\u0142\u0119boko\u015bci<\/strong> i wykaza\u0142a wy\u017cszo\u015b\u0107 nad cCHT 8 MHz<br \/>\n<a style=\"color: #004a99; text-decoration: underline;\" title=\"Comparative study on 13.56 MHz vs 8 MHz hyperthermia\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC5356646\/\" target=\"_blank\" rel=\"noopener\">(Referencje)<\/a>.<\/p>\n<\/div>\n<p>mHT dostarcza energi\u0119 termiczn\u0105 wy\u0142\u0105cznie do b\u0142ony kom\u00f3rkowej nowotworu i macierzy zewn\u0105trzkom\u00f3rkowej, wykorzystuj\u0105c temperatury poni\u017cej 43\u00b0C, rozwi\u0105zuj\u0105c ograniczenia tradycyjnej hipertermii na <strong>poziomie bliskim kom\u00f3rkowemu<\/strong>.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 320px; text-align: center;\">\n<figure style=\"margin: 0; background: #fff; padding: 15px; border: 1px solid #e1e8ed; border-radius: 8px; box-shadow: 0 4px 12px rgba(0,0,0,0.08);\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"width: 100%; height: auto; border-radius: 4px;\" title=\"Selektywny mechanizm mHT\" src=\"https:\/\/andromedichyperthermia.com\/wp-content\/uploads\/2025\/07\/modulated-RF-HT-selective-cancer-cells-300x213.jpg\" alt=\"Selektywny mechanizm celowania modulowanej hipertermii RF mHT w kom\u00f3rki nowotworowe - Modulowana Hipertermia RF 13,56MHz\" width=\"300\" height=\"213\" \/><figcaption style=\"font-size: 0.9em; text-align: left; padding-top: 15px; line-height: 1.4; color: #576574;\"><strong>Rys. 1. Selektywny mechanizm mHT.<\/strong> Modulowany pr\u0105d cz\u0119stotliwo\u015bci radiowej przep\u0142ywa g\u0142\u00f3wnie do elektrolitu zewn\u0105trzkom\u00f3rkowego, poniewa\u017c normalne kom\u00f3rki s\u0105 izolowane elektronicznie przez pole elektryczne o nat\u0119\u017ceniu ponad miliona V\/m <em>(Hegyi G, Szasz O, Szasz A. PMID: 24494322.)<\/em><\/figcaption><\/figure>\n<\/div>\n<\/div>\n<h2 style=\"color: #004a99; text-align: center; margin-bottom: 35px;\">Korzy\u015bci kliniczne modulowanej hipertermii RF (amplitudowej)<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 25px; margin-bottom: 50px;\">\n<div style=\"background: #fff; border: 1px solid #e1e8ed; border-top: 4px solid #004a99; padding: 25px; border-radius: 0 0 8px 8px;\">\n<h3 style=\"margin-top: 0; color: #004a99; font-size: 1.2em;\">Wsparcie chemioterapii i terapii biologicznej<\/h3>\n<p style=\"font-size: 0.95em;\"><strong>Lepsza perfuzja:<\/strong> Dzi\u0119ki efektowi wazodylatacji, mHT zapewnia lepsze dostarczanie substancji chemioterapeutycznych lub biologicznych <a title=\"Kosin Medical Journal: Hyperthermia outcomes\" href=\"https:\/\/www.kosinmedj.org\/journal\/view.php?number=1294\" target=\"_blank\" rel=\"noopener\">(ref)<\/a>, poprawiaj\u0105c wyniki leczenia.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e1e8ed; border-top: 4px solid #004a99; padding: 25px; border-radius: 0 0 8px 8px;\">\n<h3 style=\"margin-top: 0; color: #004a99; font-size: 1.2em;\">Radiosensytyzacja<\/h3>\n<p style=\"font-size: 0.95em;\">Zmiany w <strong>utlenowaniu<\/strong> guza i tkanek przyleg\u0142ych sprawiaj\u0105, \u017ce mHT jest doskona\u0142ym wyborem przed i po radioterapii, uwra\u017cliwiaj\u0105c guz na dzia\u0142anie promieniowania w celu zwi\u0119kszenia jego skuteczno\u015bci <a title=\"Study on radiosensitization and mHT\" href=\"https:\/\/www.kosinmedj.org\/journal\/view.php?number=1294\" target=\"_blank\" rel=\"noopener\">(ref)<\/a>.<\/p>\n<\/div>\n<div style=\"background: #fdf2f2; border: 1px solid #f8d7da; border-top: 4px solid #d9534f; padding: 25px; border-radius: 0 0 8px 8px;\">\n<h3 style=\"margin-top: 0; color: #c0392b; font-size: 1.2em;\">Efekty immunogenne (Abscopal)<\/h3>\n<p style=\"font-size: 0.9em; line-height: 1.5;\"><strong>Induktor ICD:<\/strong> mHT moduluje mikro\u015brodowisko guza (TME), wyzwalaj\u0105c <strong>DAMP<\/strong> i <strong>HSP70<\/strong>. Aktywuje to kom\u00f3rki NK oraz dojrzewanie kom\u00f3rek dendrytycznych (DC), tworz\u0105c og\u00f3lnoustrojow\u0105 odpowied\u017a na odleg\u0142e przerzuty.<\/p>\n<div style=\"font-family: monospace; font-size: 0.85em; background: #fff; padding: 10px; border-radius: 4px; border: 1px dashed #d9534f; margin-top: 10px;\">mHT (induktor ICD) -&gt; DAMP -&gt; HSP70 -&gt; DC -&gt; limfocyty T (CTL, Th1, Tmemory) -&gt; <strong>Og\u00f3lnoustrojowa odpowied\u017a przeciwnowotworowa<\/strong><\/div>\n<p style=\"font-size: 0.85em; margin-top: 10px; color: #7f8c8d;\">Wykazano wy\u017cszo\u015b\u0107 nad niwolumabem i ipilimumabem w nowotworach przewodu pokarmowego w badaniach Ralpha Kleefa i in.<br \/>\n<a title=\"Study by Ralph Kleef on mHT and Immunotherapy\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC10663566\/\" target=\"_blank\" rel=\"noopener\">(ref)<\/a>.<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #f8fbff; padding: 30px; border-radius: 12px; border: 1px solid #e1e8ed; margin-bottom: 50px;\">\n<h3 style=\"color: #004a99; margin-top: 0;\">Wyniki kliniczne: Prze\u017cycie ca\u0142kowite (OS) i jako\u015b\u0107 \u017cycia (QoL)<\/h3>\n<p>Klinicznie wielokrotnie wykazano <strong>wzrost prze\u017cycia ca\u0142kowitego (OS)<\/strong> u pacjent\u00f3w onkologicznych dzi\u0119ki dodaniu mHT, a tak\u017ce lepsz\u0105 kontrol\u0119 miejscow\u0105 guza i wy\u017csz\u0105 <strong>jako\u015b\u0107 \u017cycia (QoL)<\/strong> <a title=\"Clinical evidence on OS and QoL with mHT\" href=\"https:\/\/www.mdpi.com\/2072-6694\/15\/18\/4569\" target=\"_blank\" rel=\"noopener\">(ref)<\/a>.<\/p>\n<p style=\"font-style: italic; font-size: 0.95em; color: #576574;\">Wsparcie terapii adiuwantowej, neoadiuwantowej i paliatywnej w patologiach nowotworowych, infekcjach, stanach zapalnych oraz leczeniu b\u00f3lu.<\/p>\n<\/div>\n<section style=\"background: linear-gradient(135deg, #004a99 0%, #002d5d 100%); color: #fff; padding: 40px; border-radius: 15px; text-align: center; box-shadow: 0 10px 20px rgba(0,74,153,0.2);\">\n<h2 style=\"color: #fff; margin-top: 0; font-size: 1.8em;\">Zaawansowana mHT: Andromedic HyDeep 600WM<\/h2>\n<p style=\"font-size: 1.1em; max-width: 800px; margin: 0 auto 25px auto;\">Urz\u0105dzenie do modulowanej hipertermii Andromedic wykorzystuje 13,56 MHz jako no\u015bn\u0105 cz\u0119stotliwo\u015b\u0107 radiow\u0105 i \u0142\u0105czy j\u0105 z <strong>cz\u0119stotliwo\u015bciami radiowymi specyficznymi dla ka\u017cdej patologii i typu nowotworu<\/strong>, znacz\u0105co poprawiaj\u0105c wyniki klasycznej mHT.<\/p>\n<p><a style=\"display: inline-block; background: #ffd700; color: #002d5d; padding: 15px 35px; border-radius: 30px; text-decoration: none; font-weight: bold; font-size: 1.1em; transition: transform 0.2s;\" href=\"https:\/\/andromedichyperthermia.com\/pl\/urzadzenie-do-hipertermii-andromedic\/\"><br \/>\nPoznaj technologi\u0119 urz\u0105dzenia HyDeep 600WM<br \/>\n<\/a><\/p>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Modulowana hipertermia RF (mHT) to terapia ciep\u0142em wykorzystuj\u0105ca synergiczne efekty termiczne i nietermiczne (elektromagnetyczne) do selektywnego ogrzewania i niszczenia kom\u00f3rek nowotworowych, bez uszkadzania zdrowych tkanek. mHT stanowi innowacj\u0119 medyczn\u0105 najnowszej generacji, kt\u00f3ra dostarcza do kom\u00f3rek nowotworowych selektywn\u0105, kontrolowan\u0105 i g\u0142\u0119bok\u0105 energi\u0119 (hipertermiczn\u0105 i elektromagnetyczn\u0105) przy u\u017cyciu sprz\u0119\u017conej pojemno\u015bciowo cz\u0119stotliwo\u015bci radiowej 13,56 MHz z modulacj\u0105 amplitudy.<\/p>\n<p>System mHT 13,56 MHz wykorzystuj\u0105cy dwie elektrody posiada zdolno\u015b\u0107 penetracji tkanek do g\u0142\u0119boko\u015bci 38,4 cm i wykaza\u0142 wy\u017csz\u0105 skuteczno\u015b\u0107 w por\u00f3wnaniu do system\u00f3w cCHT pracuj\u0105cych na cz\u0119stotliwo\u015bci 8 MHz.<\/p>\n<p>Ponadto, urz\u0105dzenie mHT HyDeep 600WM firmy Andromedic wykorzystuje cz\u0119stotliwo\u015b\u0107 13,56 MHz jako fal\u0119 no\u015bn\u0105 RF i \u0142\u0105czy j\u0105 ze specyficznymi cz\u0119stotliwo\u015bciami radiowymi dla poszczeg\u00f3lnych patologii i typ\u00f3w nowotwor\u00f3w, co pozwala na potencjalne zwi\u0119kszenie skuteczno\u015bci terapeutycznej w stosunku do klasycznej metody mHT 13,56 MHz.<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3875","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/pages\/3875","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/comments?post=3875"}],"version-history":[{"count":0,"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/pages\/3875\/revisions"}],"wp:attachment":[{"href":"https:\/\/andromedichyperthermia.com\/pl\/wp-json\/wp\/v2\/media?parent=3875"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}