Andromedic HYDEEP 600WM Advanced Oncologic Hyperthermia Device: Local, Deep & Shallow Hyperthermia for Targeted Cancer Therapy – AndromedicHyperthermia / Call us Now

Andromedic HyDeep 600 WM
Advanced Modulated RF-Hyperthermia Device

The next generation of advanced oncological hyperthermia devices for cancer therapy. Delivering precisely controlled heat and electromagnetic energy selectively to cancer tissues, reaching depths of up to 38.4 cm.

advanced modulated 13.56 MHz & Pathology Specific RFs
CE / ISO 13485 / MDR / KGMP / MFDF Certified
Non-Invasive

Targeted Hyperthermia Therapy with the Andromedic HyDeep 600WM modulated RF Hyperthermia Device

The Andromedic HyDeep 600WM is a cutting-edge local hyperthermia device ( for deep & shallow cancers) designed for targeted RF-hyperthermia therapy.
It delivers precisely controlled heat + electromagnetic energy selectively to cancer tissues, offering a non-invasive treatment option for:

Superficial Tumors

Melanoma, epithelioma, cutaneous metastases, lymph node packs, superficial relapses.

Deep Seated Tumors

Sarcomas, lung cancer, pleura, pelvic cancer, bone cancer, gastrointestinal cancers (liver, pancreatic, colorectal, stomach), male & female genital cancers (ovarian, kidney & bladder & prostate cancer), brain tumors & head-neck tumors, tongue-pharyngeal cancer, laryngeal cancer, maxillofacial, jaw & cheeks cancers, etc.

Non-Oncological Pathologies:
This modulated RF hyperthermia device can also be used for inflammation, pain (including Lyme disease), endometriosis, adenomas, fibrosis, etc.

Customized Precision:
This deep local hyperthermia device has specific programmed protocols (time intervals, power in Watts, Radio Frequencies) for each pathology, adjusted according to patient’s height, weight & distance between the electrodes.

Key Features and Benefits

Advanced Modulated RF Hyperthermia (mHT)

Modulated RF-hyperthermia (mHT) is a heating therapy that uses synergized thermal and nonthermal (electromagnetic) effects to heat and destroy malignant cells in a SELECTIVE manner, without damaging healthy cells.

mHT is the latest generation medical innovation that delivers selective, controlled, and deep energy (hyperthermic + electromagnetic) using capacitively coupled 13.56 MHz amplitude modulated radiofrequency to cancer cells. The 13.56 MHz mHT with 2 electrodes can penetrate up to 38.4 cm in depth and has been shown superior to 8 MHz cCHT (ref).

modulated RF HT selective cancer cells
Fig. 1. Selective mechanism of mHT

Fig. 1. Selective mechanism of modulated RF-hyperthermia (mHT)

“Modulated radiofrequency (RF) current flows only through malignant conditions. The 13.56 MHz radiofrequency modulated current (fractally modulated) between 2 electrodes automatically focuses through malignant tissues with lower impedance and will flow mainly into the extracellular electrolyte because normal cells are electronically isolated from their membrane by more than one million V/m electric field strength.”
(Hegyi G, Szasz O, Szasz A. PMID: 24494322)

mHT has emerged as an innovative method to overcome the limitations of conventional hyperthermia. It is a far more targeted therapy, delivering thermal energy selectively only to the tumor cell membrane and extracellular matrix at temperatures below 43 °C. This solves the problem of deep selective action at the near cellular level, supported by in vivo, in vitro and human research.

The Benefits of 13.56 MHz Modulated RF Hyperthermia:


  • Better perfusion: Of chemotherapeutic or biological substances (ref) and better treatment outcomes due to the vasodilation effect.

  • Radio sensitization: Due to changes in oxygenation of tumor and adjacent tissue (ref).

  • Clinical Outcome: Improved Overall Survival (OS), local tumor control, and increased Quality of Life (QoL) (ref).

Immunogenic Cell Death (ICD):

mHT acts as a monotherapy with local and abscopal effects and is synergistic with other immunotherapies (ref).

Mechanism: mHT (ICD inducer) → DAMPs → HSP70s → DCs → activation of tumor-specific T cells (CTLs, Th1, Tmemory) → systemic cytotoxic antitumor response.

Superior to nivolumab, ipilimumab, and interleukin 2 in gastrointestinal cancers (ref).

Andromedic HyDeep 600WM HT device Innovation: We use 13.56 MHz as a carrier RF and combine it with Radio Frequencies specific for each pathology and cancer type, aiming to improve the outcomes of classical 13.56 MHz mHT.

Advanced Modulation Protocol

Andromedic HY-DEEP 600WM mHT device contains a series of cutting-edge technological features of quality and innovation that make it unique in the oncological hyperthermia market. This equipment utilizes a highly complex TMS (Thermal Modulation System) protocol, which is technologically more advanced than standard Random Noise modulation.

22 Amplitude Modulations per hour of treatment.
Hybrid Frequency: Combines 13.56 MHz RF with pathology-specific frequencies.

ASK Modulation in OOK Mode

This mHT device generates high-intensity electromagnetic impulses programmed to persist over time using ASK (Amplitude-Shift Keying) in OOK (ON-OFF Keying) mode.

“We can send more power with impulses than in continuous mode; cancer cells cannot adapt as they do in continuous mode, while healthy cells can ‘wash out’ heat during the OFF cycles.”

This modality amplifies biological effects and offers the possibility of transmitting biological information to the tissues via a pathology-specific resonant effect.

ASK modulation in OOK mode explanation

Andromedic Advanced RF Modulation VS Other 13.56 MHz RF Hyperthermia Devices

Comparison of modulation protocols

Synergistic Biological Effects

  • Vasodilation: Limiting the dissemination of malignant cells (ref).
  • Deep Hyperthermia: Penetration up to 38.4 cm (superior to 8MHz cCHT) (ref).
  • Joule Effect: Systematic increase in temperature of deep tissues (artificial fever).
  • Gene Expression: Stimulation of therapeutic gene expression and variations in protein synthesis.
  • Cellular Impact: Permeability variations and ionic displacement.
  • Oxygenation: Significant changes in oxygenation of tumor and adjacent tissue.
  • Immune Response: Release of cytokines and arrival of leukocytes; ICD (Immunogenic Cell Death) and TME modulation (ref).
  • Drug Amplification: Resonance-specific amplification of drugs, pathogens (viruses/bacteria), and organelle targeting.

2025 Intelligent Software & Remote Management

The new software of the Andromedic HY-DEEP 600WM deep hyperthermia device offers 360° device management, designed to streamline clinical workflows and ensure patient-specific precision. It can be managed remotely via WIFI connection to a server or standalone PC, integrating seamlessly with electronic medical records.

  • Data Recall: Instant access to patient therapy history, significantly speeding up preparation times.
  • Automatic Mode: Power delivery (Watts) is automatically managed based on a matrix of pre-established values.
  • Resource Optimization: Advanced automation leads to a notable reduction in professional resources required for treatment monitoring.
PC-HighPerformance Andromedic HyDeep600WM Interface
High-Performance Control Interface

Personalized Treatment Protocols

The software features specific treatment protocols for each cancer type as well as for non-oncologic pathologies, which are not generic but dynamically adjusted based on:

Patient Height
Patient Weight
Distance between Electrodes

Andromedic HY-DEEP-600 WM 2025 Design

Andromedic HY-DEEP-600 WM
NEW LOOK 2025

Global Support & Remote Troubleshooting

An additional benefit of the 2025 software is the remote monitoring and diagnosis capability. Our experts at Andromedic’s headquarters can:

  • Monitor mHT device performance in real-time.
  • Perform remote troubleshooting in case of malfunctions of the mHT device.
  • Provide distance assistance to ensure uninterrupted hyperthermia therapy sessions.

Once a problem occurs, we can see, diagnose, and fix it from a distance, minimizing downtime.

Precise Temperature Control

To ensure maximum safety and eliminate discomfort, the Andromedic HyDeep 600WM advanced oncologic hyperthermia device utilizes a sophisticated algorithm for calculating the indirect temperature of the treated area. This eliminates the need for invasive probes while preventing burns.

Safety Protocol:

Combined with real-time patient feedback, the system minimizes unwanted effects, ensuring they remain short-term and of minimal severity.

Biological Heat Management

Malignant Cells
Non-elastic vessels (simple epithelium) cannot expand. Heat is trapped, reaching 43°C for targeted apoptosis.
Healthy Cells
Elastic vascularization allows “wash out” of excess heat. Maintains 38-39°C, creating a beneficial “Artificial Fever”.

This Targeted Hyperthermia for cancer ensures that while cancer cells are destroyed, healthy tissues are not only protected but also stimulated to activate the immune system through controlled thermal stress.

Patented Antennas & Electrode Technology

The patented electrodes used by the Andromedic HyDeep 600WM local hyperthermia device  are engineered for both deep local penetration and superior patient safety. Featuring an integrated anti-burn cooling system, they ensure a high level of comfort throughout the session.

Unique Therapeutic Advantage:

“If a patient reports a burning sensation, you can reduce the electrode temperature (cool it down) without reducing the hyperthermia treatment power (Watts). This maintains maximum hyperthermia treatment efficiency while instantly restoring patient comfort.”

2 size electrodes Andromedic HyDeep 600WM
Multiple applicator options for various treatment areas

RF focus combination

By shifting the focus of the RF through the combination of antennas, it is possible to treat superficial lesions with the same deep-local hyperthermia device.

Electrode Models & Cooling

Models: 270mm and 170mm (Flexible)

Cooling System: Water-based with adjustable temperature 2°C ÷ 30°C.

Antenna Detail

Elastic Positioning Bands

Sizes: 20 cm, 80 cm, and 120 cm

Elastic bands

Antenna Spacers

Precision spacing for optimal energy delivery

Antenna spacers

Non-Invasive Cancer Treatment

Modulated RF-hyperthermia (mHT) is a purely non-invasive cancer therapy. It eliminates the risks associated with surgical interventions or invasive probes while delivering high-impact therapeutic energy deep into the body.

Potential Benefits of Hyperthermia for Cancer Patients:

*As demonstrated in multiple clinical trials, mHT provides a safe, effective, and patient-friendly addition to standard oncology protocols.

Clinical Demonstration

Watch the HY-Deep 600WM advanced oncologic hyperthermia device in a clinical setting. This video demonstrates the electrode positioning, the intuitive software interface, and the advanced 13.56 MHz technology in action.

All-In-One Hyperthermia Device

Therapeutic Excellence

    • Deep selective controlled hyperthermia
    • Electromagnetic effect synergy

vci

  • Combined 13.56 MHz RF & Resonant Frequencies ( Pathology Specific RFs)
  • Homogeneous heat diffusion

Mobility & Ergonomics

Lighter weight & easily moved: Featuring 4 industrial wheels. Move it effortlessly near the patient or between therapy rooms.

Operational Efficiency

Lower price & maintenance costs: We keep the service costs and acquisition price for our oncologic hyperthermia devices lower than our competitors. Contact us for details.

Interested in more information or a personalized quote?

CONTACT US TODAY

Andromedic HYDEEP 600WM Technical Specifications

Feature Specification
Model / Type HYDEEP 600WM / Advanced Oncologic Hyperthermia device (ASK-OOK mHT)
Emission Frequency 13.56 MHz (RF) combined with pathology specific RFs
Max. Cancer Tissue Depth 38.2 cm
Maximum Pulse Power 600 W (in ASK modulation)
Modulation Density 22 amplitude modulations per hour / Speed adaptation: 3
Refrigerated Antennas 170mm and 270mm (Integrated water cooling 6°C – 28°C)
Power Supply 230 V single-phase, 8.7 A / 50 Hz
Certification & Safety Medical Device CE MDR, ISO 13485, KGMP, Korea MFDF, EN 60601-1
Classification Class II B / Insulation Class I / Applied Parts B
Maintenance Interval Standard maintenance every 600 treatments
Physical Dimensions 150 kg | 60x80x118 cm (LxWxH)

️ No electromagnetic radiation protection structures required
✨ Comfortable treatment for the patient

Clinical Mechanism of Action

Scientific Overview for the Professional Medical Audience

Why mHT Radiofrequency?

While microwave hyperthermia only penetrate a few centimeters, 13.56 MHz Radiofrequency mHT devices achieve depths exceeding 38 cm. Modulated Hyperthermia (mHT) selectively targets the tumor cell membrane and extracellular matrix at temperatures below 43°C.

  • 3x Greater Cell Killing: mHT efficacy is three times higher than conventional hyperthermia at 42°C.
  • Biological Focus: Automatically focuses on malignant tissues without affecting healthy tissue in between.
  • Perfusion & Oxygenation: Interference with DNA repair mechanisms and improved tumor oxygenation.
Proven Efficacy Rates

Compared to conventional hyperthermia:

+45.9%
More effective at 38°C
+57.1%
More effective at 42°C

Synergistic Therapeutic Effects of Hyperthermia

With Radiotherapy

Acts as a powerful radiosensitizer. Prevents tumor cells from repairing radiation damage and increases oxygenation.

With Chemotherapy

Enhances drug perfusion through local vasodilation, increasing the response rate and local control.

With Immunotherapy

Triggers Immunogenic Cell Death (ICD) and matures dendritic cells, producing an Abscopal Effect.

Clinical Indications – modulated RF Hyperthermia

• Colorectal Cancer
• Breast Cancer Recurrences
• Cervical Cancer
• Soft Tissue Sarcoma
• Head & Neck Tumors
• Pancreatic Cancer
• Glioblastoma
• Bladder Tumors

Contraindications – modulated RF hyperthermia

Pregnancy, pacemakers or metal implants close to the treated area, thrombosis, peritoneal ascites, and patients on strong painkillers who cannot provide thermal feedback.

⏱️ Manufacturing & Delivery
Estimated 1 week. Professional installation and medical staff training included.
️ Warranty & Service
Standard EU MDR warranty with optional year-to-year extensions.
Support
A team of Andromedic professionals will travel to your site for setup and training.

Request a Clinical Consultation

Contact us for detailed hyperthermia device pricing, clinical studies, and personalized offers.

CONTACT US NOW

Copyright 2025 Premium Wellness Distrib SRL, official partner of Andromedic | +40758638401 | [email protected]